摘 要:
文章介绍传统地表水环境容量一维计算方法,针对其缺陷提出考虑不均匀系数的计算方法。介绍混合区概念及其允许范围,应用二维水质模型求解不均匀系数,并分析其计算结果。作为实例,对广西红水河某河段水环境容量进行计算,取得了很好的效果。[著者文摘]
文章出处:
《环境科学与技术》-2008年1期 -116-119页
Environmental Science and Technology
分 类 号:
文献标识码:
A
文章编号:
1003-6504(2008)01-0116-04
[参考文献]
Non-uniformity Factor in One-dimension Computation of Water Environmental Capacity
YU Lei, WU Shun-ze, FAN Li-li, XU Yi (1.Environmental Planning Academy, State Environmental Protection Administration, Beijing 100012, China ;2.School of Environmental Science and Engineering, Hohai University, Nanjing 210098, China)
Abstract:
Conventional method for computing one-dimension water environmental capacity was introduced, with non-uniformity factor taken into account. The concept of pollutant mixing zone and its allowable limit was presented, non-uniformity factor by using mathematic model of two-dimension water quality was used for computing water environmental capacity of Hongshui River, Guangxi Province and results turned out to be very effective.[著者文摘]
Key words:
water environmental capacity; one-dimension; pollutant mixing zone; non-uniformity factor
收稿日期: 2006-12-11
修订日期: 2007-03-24
基金资助:
国家环保总局“十五”科技专项-全国水和大气环境容量核定.