摘 要:
分析了高速公路双连拱隧道渗漏水产生的主要原因,从完善连拱隧道结构设计、防排水设施施工工艺的控制两方面介绍了隧道渗漏水的防治措施,以达到良好的防渗效果。[著者文摘]

文章出处:
《山西建筑》-2006年32卷16期 -299-300页
Shanxi Architecture
栏目信息:
分 类 号:
文献标识码:
A
文章编号:
1009-6825(2006)16-0299-02
相关文章:
Causes of leakage-water fault in double-continuous arch tunnel in expressway and its prevention
LEI Shuang-long
Abstract:
The author analyzes the main causes of leakage-water fault in double-continuous arch tunnel in expressway, and introduces its prevention measures from perfection of continuous arch tunnel's structural design and control of waterproof and water-drainage facilities' construction technique, in order to meet the effect of well sealing up.[著者文摘]
Key words:
double-continuous arch tunnel, leakage water, waterproof and water-drainage facility
收稿日期: 2006-02-19