摘 要:
通过对北京地铁四号线区间隧道渗漏水现象的原因进行分析,以及对拱顶以上地质地层和渗漏程度进行分析,得出需要采取注特殊浆液结合刚性防水砂浆的方法整治地铁暗挖区间隧道渗漏水的施工方法。[著者文摘]
文章出处:
《山西建筑》-2007年33卷17期 -333-334页
Shanxi Architecture
栏目信息:
分 类 号:
文献标识码:
A
文章编号:
1009-6825(2007)17-0333-02
[参考文献]
Treatment measures of the leakage water in regional tunnel of metro
MI Gang
Abstract:
Based upon analysis of the reasons caused the leakage in the regional tunnel of the No. 4 line of Beijing metro the geological stratum above areh crown and leakage degree are analyzed; at the same time treatment measures combined with grouting special mortar and rigid wa- terproof mortar are proposed to deal with leakage water in underground cutting tunnel.[著者文摘]
Key words:
metro, regional tunnel, leakage water, treatment technique
收稿日期: 2007-01-26