散热器与水源热泵串联运行利用低温地热水供暖的方法研究
下载全文
[全文大小:214 K]
张欢[1] 张文帅[1] 由世俊[1] 张成宇[2] 张璐璐[1]
[1]天津大学环境学院,天津300072 [2]南京金宸建筑设计有限公司,南京210029
摘 要:
提出了低温地热水先经过散热设备散热后再进入热泵的地热水梯级利用的方法,并建立了两种方法的[火用]分析模型.结合工程实例对二者进行的[火用]分析表明混水方法的炯效率为8.9%,地热梯级利用方法的[火用]效率为15.9%.还用寿命周期费用法对地板辐射盘管与热泵串联的经济性匹配进行了分析.[著者文摘]

文章出处:
《太阳能学报》-2007年28卷7期 -756-761页
Acta Energiae Solaris Sinica
分 类 号:
文献标识码:
A
文章编号:
0254-0096(2007)07-0756-06
[参考文献]
THE STUDY OF WATER SOURCE HEAT PUMP USING SERIAL MODE OF RADIATOR BY LOW TEMPERATURE GEOTHERMOL WATER
Zhang Huan , Zhang Wenshuai, You Shijun, Zhang Chengyu, Zhang Lulu ( 1. School of Environmental Engineering, Thanjin University, Tianjin 300072, China ; 2. Nanjing Jinchen Architecture & Design Corporation, Nanjing 210029, China)
Abstract:
Gradient utilization that geothermal water enter into the heat pump after radiation application was presented in this paper, and model of exergy analysis was created to the two methods. The exergy efficiency with mixing method and the gradient use is 8 % and 14 %, respectively . The life cycle cost method was also used to analyze the economic match of serial mode of the heat pump and floor radiation coil.[著者文摘]
Key words:
heat pump; low temperature geothermal water; heating; gradient utilization; exergy analysis
收稿日期: 2006-07-24

更多评论>>文章评论