摘  要:

为快速确定废水的污染程度,研究了运用近红外光谱法测量废水化学需氧量(COD)的可行性.实验用水样共180个,其中COD标准溶液(邻苯二甲酸氢钾标准溶液)水样22个,污水处理厂的废水水样158个.每一水样分成两组:一组测其800~2 600 nm谱区近红外光谱,另一组测其COD,并把该化学值作为标定该水样光谱的“真值”.对水样近红光谱用偏最小二乘法(PLS)回归建模,分别建立标准液水样和废水样的COD预测模型.标准液水样的理论COD值与预测值之间的相关系数为0.999 9,交叉验证均方差(RMSECV)为15.14 mg/L;污水处理厂废水水样的COD实测值与预测值之间的相关系数为0.945 3,预测标准差(RMSEP)为35.4 mg/L.实验结果表明,用近红外光谱法测量废COD是可行的.[著者文摘]

Journal of Zhejiang University(Engineering Science)

分 类 号:

TP274.52 X502

文献标识码:

A

文章编号:

1008-973X(2007)05-0752-04

相关文章:

参考文献(10篇) 耦合文献(127篇)  主题相关

[参考文献]

Determination of chemical oxygen demand in wastewater by near-infrared spectroscopy

HE Jin-cheng, YANG Xiang-long , WANG Li-ren , GUO Xi-shan (1. College of Biosystem Engineering and Food Science, Zhejiang University, Hangzhou 310029, China ;2. College of Mechanical and Electronic Engineering, Fujian Agriculture and Forestry University, Fuzhou 350002 ,China)

Abstract:

To rapidly determine the pollution extent of wastewater, the potential of near infrared (NIR) spectroscopy for measurement of chemical oxygen demand (COD) in wastewater was investigated. A total of 180 samples including 158 wastewater samples collected from Hangzhou Wastewater Treatment Plant and 22 COD standard solutions (potassium hydrogen phthalate (KHP)) prepared in laboratory. Transmission spectral measurements and dichromate method tests of 180 samples were carried out. Spectral data from 800 to 2 600 nm were collected using InGaAs detectors at 0. 717 nm resolution using a 10 mm transmission pathlength. Calibration models were developed from dichromate method as a reference method and NIR data using partial least squares (PLS) regression. The calibration model of standard solutions gave correlation coefficients of 0. 999 9 and root mean square error of cross validation (RMSECV) of 15.14 mg/ L, and the calibration model of wastewater samples gave correlation coefficients of 0. 945 3 and root mean standard error of prediction (RMSEP) of 35.4 mg/L. The results shows that NIR spectroscopy is promising for detecting COD in wastewater.[著者文摘]

Key words:

near-infrared spectroscopy; wastewater; chemical oxygen demand (COD)

收稿日期: 2006-02-03

基金资助:

福建省自然科学基金资助项目(Z0513014).

作者简介:

何金成(1973-),男,福建建宁人,博士生,主要从事农业生物环境工程研究.E~mail:hejincheng@sohu.com 通讯联系人:杨祥龙,男,教授.E-mail:xlyang@cbeis.zju.edu.cn