维普资讯
发表评论我要收藏点击“我要推荐”按钮复制地址,将本页推荐给别人看,自己就可以获得积分奖励!点击“我要推荐”按钮复制地址,推荐文章给别人看,自己就可以获得积分奖励。

280mm×380mm连铸坯结晶器电磁搅拌技术的应用

下载全文 在线阅读
[全文大小:180 K]
[在线阅读,第一页免费]

陈永[1,2] 朱苗勇[1]

[1]东北大学材料与冶金学院,沈阳110004 [2]攀枝花钢铁研究院材料研究所,攀枝花617000

特殊钢
订阅本刊
国际标准刊号:ISSN -1
国内统一刊号:CN 42-1243

摘  要:

试验研究了电磁搅拌的电流(150—500A)对重轨钢U75V等钢种(mm)280×380、280×325连铸坯冶金质量的影响。结果表明,当电流由250A提高至500A时,重轨钢U75V铸坯中心区等轴晶率由18.8%增至36.2%,夹杂总量由8.53mg/10kg降至4.68mg/10kg,中心疏松、偏析、缩孔、中心裂纹和中间裂纹等缺陷≤1.0级别的比例达98%。中碳钢连铸电磁搅拌电流为350—400A,低碳钢连铸电磁搅拌电流为250A时,铸坯内部缺陷≤1.0级的比例分别为93%和90%。[著者文摘]

文章出处:

《特殊钢》-2008年1期 -51-53页

Special Steel

栏目信息:

工艺技术

分 类 号:

TF777

相关文章:

参考文献(4篇)  主题相关

[参考文献]

Application of Mold Electromagnetic Stirring Technology for 280 mm × 380 mm Concasting Bloom

Chen Yong and Zhu Miaoyong (1 School of Materials and Metallurgy, Northeastern University, Shenyang 110004; 2 Dept of Materials Research, Panzhihua Iron and Steel Research Institute, Panzhihua 617000)

Abstract:

The effect of current (150 -500 A) of mold electromagnetic stirring (M-EMS) technology on metallurgy quality of 280 mm × 380 ram, 280 mm × 325 mm concasting bloom of heavy rail steel U75V etc grade has been tested and studied. Results showed that with the current increasing from 250 A to 500 A, the percentage of equiaxed zone increased from 18. 8% to 36. 2%, the total inclusion amount decreased from 8.53 mg/10kg to 4. 68 mg/10kg and the percentage of ratting units ≤ 1.0 of defects centre porosity, segregation, shrinkage cavity, centre cracks and midway cracks was up to 98%. As concasting stirring current was 350 - 400 A for medium carbon steels and concasting stirring current was 250 A for low carbon steels, the percentage of ratting units ≤ 1.0 of casting bloom internal defects was respectively up to 93 % and 90%.[著者文摘]

Key words:

Bloom, Concasting, M-EMS, Metallurgy Quality

收稿日期: 2007-07-23

作者简介:

陈永(1969-),男,教授级高级工程师,博士生,1990年东北大学毕业,连铸工艺和铸坯质量控制。