摘 要:
以我国某300MW直接空冷电厂为例,对空冷平台外部流场进行了数值模拟,分析不同风速对直接空冷凝汽器换热效率的影响,阐述了空冷平台边缘空气倒灌和热风回流现象产生的原因,探索提高空冷凝汽器换热效率的措施,以使直接空冷电厂能稳定经济地运行.[著者文摘]
文章出处:
《动力工程》-2008年28卷1期 -104-107页
栏目信息:
分 类 号:
文献标识码:
A
文章编号:
1000-6761(2008)01-0104-04
Numerical Simulation for the Effects of Natural Wind on Heat Exchange Efficiency of Air-cooled Condenser
ZHOU Lan-xin , BAI Zhong-hua , LI Wei-hua , ZHANG Xue-lei , (Key Lab. of Ministry of Education of Condition Plant Equipment, North China Electric Power Monitoring and Control Univ. , Baoding 071003 LI Hui-jun for Power , China)
Abstract:
The exterior flow field of air-cooled platform was numerically air-cooled unit. The effects of different wind velocity on heat exchan condenser were analyzed. The cause of air inverse flow at the edge of plat was expounded. The measures to enhance the heat exchange efficiency lated for one 300 MW direct ge efficiency of direct air-cooled form and the hot air re-circulation of the air-cooled condenser were explored so as to make the direct air-cooled unit operate stably and economically.[著者文摘]
Key words:
energy and power engineering; direct air cooling; condenser; numerical simulation; heatexchange; flow field

学术